Product Details

CPR Series
CPR-165 / CPR-390

  • Model:CPR-165 / CPR-390
About this product
◆ Can dry rapidly, evenly at low temperature.
◆ The rate of broken rice would be low and the appearance rice will be beautiful, achieving high milling yield.
◆ Can use rice husk as biomass fuel to minimize drying costs.

    Product Introduction

    CPR-165 Series / CPR-390 Series
    • The low-temp., even and speedy drying minimizes broken grains and produces beautiful kernels.
    • The entire dryer is designed to be strong and sturdy, making it suitable for heavy-duty.
    • With foolproof design, users can dry high-quality grain from the 1st, 100th to 1000th batch. 
      Grain consistent in quality will be available to customers.

    • Automatic moisture control prevents over-drying and weight loss.
    • By using self-milled free rice husk, users no longer need to spend on diesel, 
      natural gas or electricty as dryers' heat sources.



    Multiple models with various fuel options availabl
    Heat SourceCPR-165 SeriesCPR-390 Series
    Diesel
    Gas
    Husk
    Biomass
    Steam
    Diesel & Husk Dual
    Gas & Husk Dual
    CL-10 Unit12


    Application
    Paddy
    wheat
    corn


    Specifications
    ItemCPR-165
    Low-temp
    CPR-165
    High-temp
    CPR-390
    Heat SourceKerosene or Premium Diesel*
    Combustion    Approx. liter/hr8.8~2317.5~2727~54
    Capacity         
    Approx. kg
    Paddy
    1 liter=560g
    6,500~13,25014,800~32,100
    Rapeseed
    1 liter=680g
    7,500~16,32018,000~39,000
    Wheat
    1 liter=680g
    Pulses, Corn
    1 liter=690g
    7,500~16,35018,300~39,600
    Dimension     
    L×W×Hmm
    (A)×(B)×(C)mm
    Without CL-105,007×2,745×9,6716,385×4,820×13,694
    With 
    CL-10
    Horizontal
    Type
    8,012×2,745×9,6718,765×4,820×13,694
    Vertical
    Type
    Please contact
    the sales department
    Please contact
    the sales department
    Net Weight     
    Approx. kg
    Without CL-103,1709,200
    With 
    CL-10
    Horizontal
    Type
    3,71810,200
    Vertical
    Type
    Please contact
    the sales department
    Please contact
    the sales department
    Power 
    Consumption

    kW
    Without CL-106.4513.8
    With CL-1010.2521.4
    FunctionLoading         
    Approx. mins
    Paddy 66
    Rapeseed/Pulses 60
    Pulses/Corn
    75
    Paddy 56
    Rapeseed/Pulses 67
    Discharging
    Approx. mins
    Paddy/Rapeseed/Pulses
    65
    Pulses/Corn
    70
    Paddy 51
    Rapeseed/Pulses 60
    Drying
    Rate

    %/hr
    Commercial
    Grains
    0.5~1.2Pulses/Corn
    1.0~2.0
    0.5~1.2
    SeedPaddy/Wheat 0.2~1.0
    Rapeseed 0.1~0.5
    Paddy/Wheat 0.2~1.0
    Rapeseed 0.1~0.5
    TypeGun type
    Electricity 3P, 220V/380V/415V/440V, 50/60Hz
    Safety DevicesThermo-over relay, Air pressure switch,
    Full load buzzer, Timer, Control fuse,
    Flame sensor, Over heat sensor.
    *Use high-quality kerosene or premium diesel only


     
    ItemCPR-165GCPR-390G
    Heat SourceLPGNGLPGNG
    Max. Combustion      Approx.25 kg/hr27.3 m3/hr49.8 kg/hr54.5 m3/hr
    Capacity         
    Approx. kg
    Paddy
    1 liter=560g
    6,500~13,25014,800~32,100
    Rapeseed
    1 liter=680g
    7,500~16,32018,000~39,000
    Wheat
    1 liter=680g
    Pulses, Corn
    1 liter=690g
    7,500~16,35018,300~39,600
    Dimension     
    L×W×Hmm
    (A)×(B)×(C)mm
    Without CL-105,007×3,210×9,6716,385×4,820×13,694
    With
    CL-10
    Horizontal
    Type
    8,012×3,210×9,6718,765×4,820×13,694
    Vertical
    Type
    Please contact
    the sales department
    Please contact
    the sales department
    Net Weight     
    Approx. kg
    Without CL-103,1709,200
    With
    CL-10
    Horizontal
    Type
    3,71810,200
    Vertical
    Type
    Please contact
    the sales department
    Please contact
    the sales department
    Power Consumption
    kW
    Without CL-106.614.2
    With CL-1010.421.8
    FunctionLoading
    Approx. mins
    Paddy 66
    Rapeseed/Pulses 60
    Paddy 56
    Rapeseed/Pulses 67
    Discharging
    Approx. mins
    Paddy/Rapeseed/Pulses 65Paddy 51
    Rapeseed/Pulses 60
    Drying
    Rate
       
    %/hr
    Commercial
    Grains
    Paddy/Wheat/Rapeseed 0.5~1.2
    Pulses/Corn 1.0~2.0
    0.5~1.2
    SeedPaddy/Wheat 0.2~1.0
    Rapeseed 0.1~0.5
    Paddy/Wheat 0.2~1.0
    Rapeseed 0.1~0.5
    TypeGun type
    Electricity 3P, 220V/380V/415V/440V, 50/60Hz
    Safety DevicesThermo-over relay, Air pressure switch,
    Full load buzzer, Timer, Control fuse,
    Flame sensor, Over heat sensor.


     
    ItemCPR-165BCPR-390B
    Heat SourceSUNCUE
    Biomass Furnace BB-18,
    Rice Husk Furnace SB
    SUNCUE
    Rice Husk Furnace SB
    Capacity         
    Approx. kg
    Paddy
    1 liter=560g
    6,500~13,25014,800~32,100
    Rapeseed
    1 liter=680g
    7,500~16,32018,000~39,000
    Wheat
    1 liter=680g
    Pulses, Corn
    1 liter=690g
    7,500~16,35018,300~39,600
    Dimension     
    L×W×Hmm
    (A)×(B)×(C)mm
    Without CL-105,565×2,675×9,6717,990×4,820×13,694
    With
    CL-10
    Horizontal
    Type
    8,570×2,675×9,67110,370×4,820×13,694
    Vertical
    Type
    Please contact
    the sales department
    Please contact
    the sales department
    Net Weight     
    Approx. kg
    Without CL-103,42010,000
    With
    CL-10
    Horizontal
    Type
    3,96811,000
    Vertical
    ype
    Please contact
    the sales department
    Please contact
    the sales department
    Required
    Thermal
    Energy

    Per Unit 
    Approx. Kcal/hr
    Paddy, Rapeseed, Wheat36,000~145,000
    Ambient Temp. +10~40°C
    83,000~330,000
    Ambient Temp. +10~40°C
    Pulses, Corn36,000~235,000
    Ambient Temp. +10~65°C
    560,000
    Ambient Temp. +65°C
    Power
    Consumption

    kW
    Without CL-107.716.84
    With CL-1011.524.44
    FunctionLoading
    Approx. mins
    Paddy 66
    Rapeseed/Pulses 60
    Paddy 56‧Rapeseed 67
    Discharging
    Approx. mins
    Paddy/Rapeseed/Pulses 65Paddy 51‧Rapeseed 60
    Drying
    Rate
       
    %/hr
    Commercial
    Grains
    Paddy/Wheat/Rapeseed 0.5~1.2
    Pulses/Corn 1.0~2.0
    0.5~1.2
    SeedPaddy/Wheat 0.2~1.0
    Rapeseed 0.1~0.5
    Paddy/Wheat 0.2~1.0
    Rapeseed 0.1~0.5
    Electricity 3P, 220V/380V/415V/440V, 50/60Hz
    Safety DevicesThermo-over relay,
    Air pressure switch,  
    Full load buzzer, Timer,
    Control fuse.
    Thermo-over relay,
    Air pressure switch,
    Full load buzzer, Timer,
    Control fuse, Rotation sensor.



    ItemCPR-165S-7CPR-165S-12
    Heat SourceSteam
    Capacity         
    Approx. kg
    Paddy             1 liter=560g6,500~13,250
    Rapeseed       1 liter=680g7,500~16,320
    Wheat             1 liter=680g
    Pulses, Corn  1 liter=690g7,500~16,350
    Dimension     
    L×W×Hmm
    (A)×(B)×(C)mm
    Without CL-104,820×2,890×9,6715,160×2,890×9,671
    With CL-10Horizontal Type7,825×2,890×9,6718,165×2,890×9,671
    Vertical TypePlease contact
    the sales department
    Please contact
    the sales department
    Net Weight     
    Approx. kg
    Without CL-103,5203,620
    With CL-10Horizontal Type4,0684,168
    Vertical TypePlease contact
    the sales department
    Please contact
    the sales department
    Applicable GrainsPaddy/Rapeseed
    Wheat
    Paddy/Rapeseed
    Wheat/Pulses
    Corn
    Temperature  Increase Range     
    Ambient Temp Approx.
    +15~50°C+15~63°C
    Boiler Capacity    Approx. ton/hr  0.60.8
    Boiler Pressure    Approx. kg/cm²7
    Power Consumption
    kW
    Without CL-106.2
    With CL-1010
    FunctionLoading          Approx. minsPaddy 66
    Rapeseed/Pulses 60
    Discharging   Approx. minsPaddy/Rapeseed/Pulses 65
    Drying Rate   
    %/hr
    Commercial GrainsPaddy/Wheat/Rapeseed 0.5~1.2
    Pulses/Corn 1.0~2.0
    SeedPaddy/Wheat 0.2~1.0
    Rapeseed 0.1~0.5
    Electricity 3P, 220V/380V/415V/440V, 50/60Hz
    Safety DevicesThermo-over relay,  Air pressure switch,  
    Full load buzzer, Timer,  Control fuse.
     


    Dimensions  Unit mm





    contact
    catalog
    maintenance
    Q&A

     

    Product Remark

    ◆Above numbers and drying rate are derived from reducing moisture in paddy from 26% to 15%, wheat/corn from 30% to 12.5% ─ for reference only. Actual results vary among different ambient temperature, relative humidity, grain varieties, hot air temperature, moisture content before and after drying.
    ◆Please apply low hot air temperature for drying paddy to prevent high breakage rate.
    ◆Gas pipe lines have to be built by certified local professionals. NEVER do it by yourself.
    ◆The required thermal energy is for reference only. Actual data will differ among grain variety, impurity rate, and drying condition.
    ◆The specification and graph are for reference only. Actual specification of SUNCUE product shall be based on the Sales Confirmation which customers sign and delivered products.
    ◆The specifications of burner shown above are Japanese standard (Thermal energy: NG 11,000 Kcal/m³; LPG 12,000 Kcal/kg). Please consult with SUNCUE for burner with CE standard.
    ◆The density, composition and pressure of natural gas vary at different locations, thus thermal energy per m³ also varies. Ex: 8,900Kcal/m³ in Taiwan, 11,000Kcal/m³ in Japan, 8,400Kcal/m³ in Sichuan province of China.
    ◆Only use kerosene or premium diesel or diesel conformed to national standards. Please choose good quality diesel that can completely vaporize according to ambient temperature.
    ◆Boiler is a dangerous device. It should be installed in a boiler house and operated by professionally-trained personnel with official license by laws. The operation must obey local government regulations.
    ◆Different platform, rain hood, exhaust chamber, exhaust pipe, stand, balustrade and other accessories are required for each dryer and CL-10 model.
    ◆The user shall prepare dust collecting bags when using CL-10 without a central dust collecting system.

    Related Products