- Product
Product Details
CPR Series
CPR-165
About this product
◆ Can dry rapidly, evenly at low temperature.
◆ The rate of broken rice would be low and the appearance rice will be beautiful, achieving high milling yield.
◆ Can use rice husk as biomass fuel to minimize drying costs.
Product Introduction
CPR-165 Series • The low-temp., even and speedy drying minimizes broken grains and produces beautiful kernels.
• The entire dryer is designed to be strong and sturdy, making it suitable for heavy-duty.
• With foolproof design, users can produce high-quality rice from the 1st, 100th to 1000th batch.
Grain consistent in quality will be available to customers.
• Automatic moisture control prevents over-drying and weight loss.
• By using self-milled free rice husk, users no longer need to spend on diesel, natural gas or electricty as dryers' heat sources.
Multiple models with various fuel options availabl Heat Source | CPR-165 Series |
Diesel | ● |
Gas | ● |
Biomass | ● |
Steam | ● |
Application SpecificationsItem | CPR-165 Low-temp | CPR-165 High-temp |
Heat Source | Kerosene or Premium Diesel* |
Combustion Approx. liter/hr | 8.8~23 | 17.5~27 |
Capacity Approx. kg | Paddy 1 liter=560g | 6,500~13,250 | - |
Rapeseed 1 liter=690g | 7,500~16,350 | - |
Wheat 1 liter=680g |
Pulses, Corn 1 liter=690g | 7,500~16,350 |
Dimension L(A)×W(B)×H(C) mm | Without CL-10 | 5,007×2,745×9,671 |
With CL-10 | Horizontal Type | 8,012×2,745×9,671 |
Vertical Type | Please contact the sales department |
Net Weight Approx. kg | Without CL-10 | 3,170 |
With CL-10 | Horizontal Type | 3,718 |
Vertical Type | Please contact the sales department |
Power Consumption kW | Without CL-10 | 6.45 |
With CL-10 | 10.25 |
Function | Loading Approx. mins | Paddy 72 Rapeseed/Pulses 60 | Pulses/Corn 60 |
Discharging Approx. mins | Paddy/Rapeseed/Pulses 66 | Pulses/Corn 66 |
Drying Rate %/hr | Commercial Grains | 0.5~1.2 | Pulses/Corn 1.0~2.0 |
Seed | Paddy/Wheat 0.2~1.0 Rapeseed 0.1~0.5 | - |
Type | Gun type |
Electricity | 3P, 220V/380V/415V/440V, 50/60Hz |
Safety Devices | Thermo-over realy, Air pressure switch, Full load buzzer, Timer, Control fuse, Flame sensor, Over heat sensor. |
*Use high-quality kerosene or premium diesel only Item | CPR-165G |
Heat Source | LPG | NG |
Combustion Approx. liter/hr | Max. 25kg/hr | Max. 27.3m3/hr |
Capacity Approx. kg | Paddy 1 liter=560g | 6,500~13,250 |
Rapeseed 1 liter=690g | 7,500~16,350 |
Wheat 1 liter=680g |
Pulses, Corn 1 liter=690g |
Dimension L(A)×W(B)×H(C) mm | Without CL-10 | 5,007×3,210×9,671 |
With CL-10 | Horizontal Type | 8,012×3,210×9,671 |
Vertical Type | Please contact the sales department |
Net Weight Approx. kg | Without CL-10 | 3,170 |
With CL-10 | Horizontal Type | 3,718 |
Vertical Type | Please contact the sales department |
Power Consumption kW | Without CL-10 | 6.6 |
With CL-10 | 10.4 |
Function | Loading Approx. mins | Paddy72 Rapeseed/Pulses 60 |
Discharging Approx. mins | Paddy/Rapeseed/Pulses 66 |
Drying Rate %/hr | Commercial Grains | Paddy/Wheat/Rapeseed 0.5~1.2 Pulses/Corn 1.0~2.0 |
Seed | Paddy/Wheat 0.2~1.0 Rapeseed 0.1~0.5 |
Type | Gun type |
Electricity | 3P, 220V/380V/415V/440V, 50/60Hz |
Safety Devices | Thermo-over realy, Air pressure switch, Full load buzzer, Timer, Control fuse, Flame sensor, Over heat sensor. |
Item | CPR-165B |
Heat Source | SUNCUE Biomass Furnace BB-18, Rice Husk Furnace SB |
Capacity Approx. kg | Paddy 1 liter=560g | 6,500~13,250 |
Rapeseed 1 liter=690g | 7,500~16,350 |
Wheat 1 liter=680g |
Pulses, Corn 1 liter=690g |
Dimension L(A)×W(B)×H(C) mm | Without CL-10 | 5,565×2,675×9,671 |
With CL-10 | Horizontal Type | 8,570×2,675×9,671 |
Vertical Type | Please contact the sales department |
Net Weight Approx. kg | Without CL-10 | 3,420 |
With CL-10 | Horizontal Type | 3,968 |
Vertical Type | Please contact the sales department |
Required Thermal Energy Per Unit Approx. Kcal/hr | Paddy, Rapeseed, Wheat | 36,000~145,000 Ambient Temp. +10~40°C |
Pulses | 36,000~235,000 Ambient Temp. +10~65°C |
Corn | 45,000~267,000 Ambient Temp. +10~60°C |
Power Consumption kW | Without CL-10 | 7.7 |
With CL-10 | 11.5 |
Function | Loading Approx. mins | Paddy 72 Rapeseed/Pulses 60 |
Discharging Approx. mins | Paddy/Rapeseed/Pulses66 |
Drying Rate %/hr | Commercial Grains | Paddy/Wheat/Rapeseed 0.5~1.2 Pulses/Corn 1.0~2.0 |
Seed | Paddy/Wheat 0.2~1.0 Rapeseed 0.1~0.5 |
Electricity | 3P, 220V/380V/415V/440V, 50/60Hz |
Safety Devices | Thermo-over relay, Air pressure switch, Full load buzzer, Timer, Control fuse. |
Item | CPR-165S-7 | CPR-165S-12 |
Heat Source | Steam |
Capacity Approx. kg | Paddy 1 liter=560g | 6,500~13,250 |
Rapeseed 1 liter=690g | 7,500~16,350 |
Wheat 1 liter=680g |
Pulses, Corn 1 liter=690g |
Dimension L(A)×W(B)×H(C) mm | Without CL-10 | 4,820×2,890×9,671 | 5,160×2,890×9,671 |
With CL-10 | Horizontal Type | 7,825×2,890×9,671 | 8,165×2,890×9,671 |
Vertical Type | Please contact the sales department | Please contact the sales department |
Net Weight Approx. kg | Without CL-10 | 3,520 | 3,620 |
With CL-10 | Horizontal Type | 4,068 | 4,168 |
Vertical Type | Please contact the sales department | Please contact the sales department |
Applicable Grains | Paddy/Rapeseed Wheat | Paddy/Rapeseed Wheat/Pulses Corn |
Temperature Increase Range Ambient Temp Approx. | +15~50°C | +15~63°C |
Boiler Capacity Approx. ton/hr | 0.6 | 0.8 |
Boiler Pressure Approx. kg/cm² | 7 |
Power Consumption kW | Without CL-10 | 6.2 |
With CL-10 | 10 |
Function | Loading Approx. mins | Paddy 72 Rapeseed/Pulses 60 |
Discharging Approx. mins | Paddy/Rapeseed/Pulses 66 |
Drying Rate %/hr | Commercial Grains | Paddy/Wheat/Rapeseed 0.5~1.2 Pulses/Corn 1.0~2.0 |
Seed | Paddy/Wheat 0.2~1.0 Rapeseed 0.1~0.5 |
Electricity | 3P, 220V/380V/415V/440V, 50/60Hz |
Safety Devices | Thermo-over relay, Air pressure switch, Full load buzzer, Timer, Control fuse. |
Dimensions Unit mm
Product Remark
◆Above numbers and drying rate are derived from reducing moisture in paddy from 26% to 15%, wheat/corn from 30% to 12.5% ─ for reference only. Actual results vary among different ambient temperature, relative humidity, grain varieties, hot air temperature, moisture content before and after drying.
◆Please apply low hot air temperature for drying paddy to prevent high breakage rate.
◆Gas pipe lines have to be built by certified local professionals. NEVER do it by yourself.
◆The required thermal energy is for reference only. Actual data will differ among grain variety, impurity rate, and drying condition.
◆The specification and graph are for reference only. Actual specification of SUNCUE product shall be based on the Sales Confirmation which customers sign and delivered products.
◆The specifications of burner shown above are Japanese standard (Thermal energy: NG 11,000 Kcal/m³; LPG 12,000 Kcal/kg). Please consult with SUNCUE for burner with CE standard.
◆The density, composition and pressure of natural gas vary at different locations, thus thermal energy per m³ also varies. Ex: 8,900Kcal/m³ in Taiwan, 11,000Kcal/m³ in Japan, 8,400Kcal/m³ in Sichuan province of China.
◆Only use kerosene or premium diesel or diesel conformed to national standards. Please choose good quality diesel that can completely vaporize according to ambient temperature.
◆Boiler is a dangerous device. It should be installed in a boiler house and operated by professionally-trained personnel with official license by laws. The operation must obey local government regulations.
◆Different platform, rain hood, exhaust chamber, exhaust pipe, stand, balustrade and other accessories are required for each dryer and CL-10 model.
◆The user shall prepare dust collecting bags when using CL-10 without a central dust collecting system.