- Product
Product Details
SUPER Series
SUPER-300
About this product
◆ Can dry rapidly, evenly at low temperature.
◆ The rate of broken rice would be low and the appearance rice will be beautiful, achieving high milling yield.
◆ Can use rice husk as biomass fuel to minimize drying costs.
Product Introduction
SUPER-300 Series • The low-temp., even and speedy drying minimizes broken rice, raises milling rate and produces beautiful rice.
• The entire dryer is designed to be strong and sturdy, making it suitable for heavy-duty.
• With foolproof design, users can produce high-quality rice from the 1st, 100th to 1000th batch.
Small-package rice consistent in quality will be available to customers.
• Automatic moisture control prevents over-drying and weight loss.
• By using self-milled free rice husk, users no longer need to spend on diesel, natural gas or electricty as dryers' heat sources.
Multiple models with various fuel options availabl Heat Source | SUPER-300 Series |
Diesel | ● |
Gas | ● |
Biomass | ● |
Diesel & Husk Dual | ● |
Gas & Husk Dual | - |
Steam | ● |
Application SpecificationsItem | SUPER-300 |
Heat Source | Kerosene or Premium Diesel* |
Type | Gun type |
Combustion Approx. liter/hr | 17.5~35 |
Capacity Approx. kg | Paddy 1 liter=560g | 4,000~30,000 |
Wheat 1 liter=680g | 5,000~36,400 |
Corn, Animal Feed 1 liter=690g | 5,000~36,900 |
Dimension L(A)×W(B)×H(C) mm | Without CL-10 | 4,786×3,786×11,629 |
With CL-10 | Horizontal Type | 7,896×3,786×11,629 |
Vertical Type | 6,997×4,031×11,629 |
Net Weight Approx. kg | Without CL-10 | 5,150 |
With CL-10 | Horizontal Type | 6,290 |
Vertical Type | 6,623 |
Power Consumption kW | Without CL-10 | 13.48 |
With CL-10 | 21.05 |
Function Paddy | Loading Approx. mins | 65 |
Discharging Approx. mins | 70 |
Drying Rate %/hr | 0.5~1.5 |
Electricity | 3P, 220V/380V/415V/440V, 50/60Hz |
Safety Devices | Thermo-over relay, Air pressure switch, Full load buzzer, Timer, Flame sensor, Control fuse, Abnormal combustion sensor |
*Use high-quality kerosene or premium diesel only Item | SUPER-300B |
Heat Source | SUNCUE Biomass Furnace BB-18 for seeds Rice Husk Furnace SB |
Capacity Approx. kg | Paddy 1 liter=560g | 4,000~30,000 |
Wheat 1 liter=680g | 5,000~36,400 |
Corn, Animal Feed 1 liter=690g | 5,000~36,900 |
Dimension L(A)×W(B)×H(C) mm | Without CL-10 | 4,999×3,786×11,629 |
With CL-10 | Horizontal Type | 8,129×3,786×11,629 |
Vertical Type | 7,230×4,031×11,629 |
Net Weight Approx. kg | Without CL-10 | 5,200 |
With CL-10 | Horizontal Type | 6,419 |
Vertical Type | 6,752 |
Required Thermal Energy Approx. per unit | Paddy ‧ Wheat Approx. Kcal/hr | 65,000~260,000 Ambient Temp. +10~40°C |
Corn ‧ Animal Feed Approx. Kcal/hr | 75,000~450,000 Ambient Temp. +10~60°C |
Power Consumption kW | Without CL-10 | 16.75 |
With CL-10 | 24.35 |
Function Paddy | Loading Approx. mins | 65 |
Discharging Approx. mins | 70 |
Drying Rate %/hr | 0.5~1.5 |
Electricity | 3P, 220V/380V/415V/440V, 50/60Hz |
Safety Devices | Thermo-over relay, Air pressure switch, Full load buzzer, Timer, Control fuse |
Item | SUPER-300G |
Heat Source | LPG | NG |
Max. Combustion Approx. | 41.6kg/hr≒581kW | 45.5m3/hr≒581kW |
Type | Gun type |
Capacity Approx. kg | Paddy 1 liter=560g | 4,000~30,000 |
Wheat 1 liter=680g | 5,000~36,400 |
Corn, Animal Feed 1 liter=690g | 5,000~36,900 |
Dimension L(A)×W(B)×H(C) mm | Without CL-10 | 4,786×4,112×11,629 |
With CL-10 | Horizontal Type | 7,896×4,112×11,629 |
Vertical Type | 6,997×4,171×11,629 |
Net Weight Approx. kg | Without CL-10 | 5,150 |
With CL-10 | Horizontal Type | 6,290 |
Vertical Type | 6,623 |
Power Consumption kW | Without CL-10 | 13.8 |
With CL-10 | 21.4 |
Function Paddy | Loading Approx. mins | 65 |
Discharging Approx. mins | 70 |
Drying Rate %/hr | 0.5~1.5 |
Electricity | 3P, 220V/380V/415V/440V, 50/60Hz |
Safety Devices | Thermo-over relay, Air pressure switch, Full load buzzer, Timer, Flame sensor, Control fuse, Abnormal combustion sensor |
Item | SUPER-300S |
5 | 7 | 12 |
Heat Source | Steam |
Capacity Approx. kg | Paddy 1 liter=560g | 4,000~30,000 |
Wheat 1 liter=680g | 5,000~36,400 |
Corn, Animal Feed 1 liter=690g | 5,000~36,900 |
Dimension mm | Without CL-10 | Length(A) | 4,302 | 4,395 | 4,745 |
Width(B) | 3,786 | 3,786 | 3,786 |
Height(C) | 11,629 | 11,629 | 11,629 |
With CL-10 | Horizontal Type | Length(A) | 7,412 | 7,505 | 7,855 |
Width(B) | 3,786 | 3,786 | 3,786 |
Height(C) | 11,629 | 11,629 | 11,629 |
Vertical Type | Length(A) | 6,513 | 6,606 | 6,956 |
Width(B) | 4,031 | 4,031 | 4,031 |
Height(C) | 11,629 | 11,629 | 11,629 |
Net Weight Approx. kg | Without CL-10 | 5,210 | 5,265 | 5,420 |
With CL-10 | Horizontal Type | 6,350 | 6,405 | 6,560 |
Vertical Type | 6,683 | 6,738 | 6,893 |
Power Consumption kW | Without CL-10 | 13.1 |
With CL-10 | 20.7 |
Function Paddy | Loading Approx. mins | 65 |
Discharging Approx. mins | 70 |
Drying Rate %/hr | 0.5~1.5 |
Applicable Region | Regular | Cold | Frigid |
Applicable Grains | Paddy, Wheat | Paddy, Wheat, Maize |
Temp. Increase Range Ambient Temp. | +25~42°C | +41~71°C | +21~86°C |
Boiler Capacity Approx. ton/hr | 1.0 | 1.8 | 2.2 |
Boiler Pressure Approx. kg/cm² | 7 |
Electricity | 3P, 220V/380V/415V/440V, 50/60Hz |
Safety Devices | Thermo-over relay, Air pressure switch, Full load buzzer, Timer, Control fuse |
Dimensions Unit mm
Product Remark
◆ Above numbers and drying rate are derived from reducing moisture in paddy from 26% to 15%, wheat/corn from 30% to 12.5% ─ for reference only. Actual results vary among different ambient temperature, relative humidity, grain varieties, hot air temperature, moisture content before and after drying.
◆ Please apply low hot air temperature for drying paddy to prevent high breakage rate.
◆ The specifications of burner shown above are Japanese standard (Thermal energy: NG 11,000 Kcal/m³; LPG 12,000 Kcal/kg).Please consult with SUNCUE for burner with CE standard.
◆ The user shall prepare dust collecting bags when using CL-10 without a central dust collecting system.
◆ Different platform, rain hood, exhaust chamber, exhaust pipe, stand, balustrade and other accessories are required for each dryer and CL-10 model.
◆ Gas pipe lines have to be built by certified local professionals. NEVER do it by yourself.
◆ The required thermal energy is for reference only. Actual data will differ among grain variety, impurity rate, and drying condition.
◆ Diesel/Rice Husk & Gas/Rice Husk Duel-type are made to order.
◆ The specification and graph are for reference only. Actual specification of SUNCUE product shall be based on the Sales Confirmation which customers sign and delivered products.
◆ The density, composition and pressure of natural gas vary at different locations, thus thermal energy per m³ also varies. Ex: 8,900Kcal/m³ in Taiwan, 11,000Kcal/m³ in Japan, 8,400Kcal/m³ in Sichuan province of China.
Related Products