Product Details

SUPER Series
SUPER-60

  • Model:SUPER-60
About this product
◆ Can dry rapidly, evenly at low temperature.
◆ The rate of broken rice would be low and the appearance rice will be beautiful, achieving high milling yield.
◆ Can use rice husk as biomass fuel to minimize drying costs.

    Product Introduction

    SUPER-60 Series
    • The low-temp., even and speedy drying minimizes broken rice, raises milling rate and produces beautiful rice.
    • The entire dryer is designed to be strong and sturdy, making it suitable for heavy-duty.
    • With foolproof design, users can produce high-quality rice from the 1st, 100th to 1000th batch. 
       Small-package rice consistent in quality will be available to customers.
    • Automatic moisture control prevents over-drying and weight loss.
    • By using self-milled free rice husk, users no longer need to spend on diesel, natural gas or electricty as dryers' heat sources.


    Multiple models with various fuel options availabl
    Heat SourceSUPER-60 Series
    Diesel
    Gas
    Biomass
    Diesel & Husk Dual-
    Gas & Husk Dual-
    Steam-


    Application
    Paddy
    wheat
    corn


    Specifications
    ItemSUPER-60
    Heat SourceKerosene or Premium Diesel*
    TypeGun type
    Combustion    Approx. liter/hr4.4~11
    Capacity         
    Approx. kg
    Paddy    1 liter=560g2,500~6,000
    Wheat    1 liter=680g3,035~7,285
    Corn, Animal Feed   
    1 liter=690g
    3,080~7,390
    Dimension      L(A)×W(B)×H(C) mm3,270×2,660×6,220
    Net Weight      Approx. kg1,785
    Electricity1P/3P, 220V/380V/415V/440V, 50/60Hz
    Power Consumption   kW1P:3.1      3P:4.07
    Function
    Paddy
    Loading          Approx. mins30
    Discharging   Approx. mins41
    Drying Rate    %/hr0.5~1.5
    Safety DevicesThermo-over relay, Air pressure switch,
    Full load buzzer, Timer, Flame sensor,
    Control fuse, Abnormal combustion sensor
    *Use high-quality kerosene or premium diesel only
     
    ItemSUPER-60B
    Heat SourceSUNCUE Biomass Furnace BB-18,
    Rice Husk Furnace SB-40 / SB-80
    Capacity         
    Approx. kg
    Paddy    1 liter=560g2,500~6,000
    Wheat    1 liter=680g3,035~7,285
    Corn, Animal Feed   1 liter=690g3,080~7,390
    Dimension      L(A)×W(B)×H(C) mm3,754×2,660×6,220
    Net Weight      Approx. kg1,955
    Required Thermal Energy 
    Approx. per unit
    Paddy, Wheat   Approx. Kcal/hr25,000~100,000
    Ambient Temp. +10~40°C
    Corn, Animal Feed   Approx. Kcal/hr30,000~180,000
    Ambient Temp. +10~60°C
    Electricity3P, 220V/380V/415V/440V, 50/60Hz
    Power Consumption    kW5.5
    Function
    Paddy
    Loading          Approx. mins30
    Discharging   Approx. mins31
    Drying Rate    %/hr0.5~1.5
    Safety DevicesThermo-over relay, Air pressure switch,
    Full load buzzer, Timer, Control fuse


    ItemSUPER-60G
    Heat SourceLPGNG
    Max. Combustion     Approx.12.6kg/hr≒174kW13.6m3/hr≒174kW
    TypeGun type
    Capacity         
    Approx. kg
    Paddy    1 liter=560g2,500~6,000
    Wheat    1 liter=680g3,035~7,285
    Corn, Animal Feed   
    1 liter=690g
    3,080~7,390
    Dimension      L(A)×W(B)×H(C) mm3,317×3,232×6,220
    Net Weight      Approx. kg1,785
    Electricity1P/3P, 220V/380V/415V/440V, 50/60Hz
    Power Consumption    kW1P:3.3      3P:4.25
    Function
    Paddy
    Loading          Approx. mins30
    Discharging   Approx. mins41
    Drying Rate    %/hr0.5~1.5
    Safety DevicesThermo-over relay, Air pressure switch,
    Full load buzzer, Timer, Flame sensor,
    Control fuse, Abnormal combustion sensor

    Dimensions  
    Unit mm

     
    contact
    catalog
    maintenance
    Q&A

     

    Product Remark

    ◆Above numbers and drying rate are derived from reducing moisture in paddy from 26% to 15%, wheat/corn from 30% to 12.5% ─ for reference only. Actual results vary among different ambient temperature, relative humidity, grain varieties, hot air temperature, moisture content before and after drying.
    ◆Please apply low hot air temperature for drying paddy to prevent high breakage rate.
    ◆The specifications of burner shown above are Japanese standard (Thermal energy: NG 11,000 Kcal/m³; LPG 12,000 Kcal/kg).Please consult with SUNCUE for burner with CE standard.
    ◆Gas pipe lines have to be built by certified local professionals. NEVER do it by yourself.
    ◆The required thermal energy is for reference only. Actual data will differ among grain variety, impurity rate, and drying condition.
    ◆The specification and graph are for reference only. Actual specification of SUNCUE product shall be based on the Sales Confirmation which customers sign and delivered products.
    ◆The density, composition and pressure of natural gas vary at different locations, thus thermal energy per m³ also varies. Ex: 8,900Kcal/m³ in Taiwan, 11,000Kcal/m³ in Japan, 8,400Kcal/m³ in Sichuan province of China.

    Related Products